Cover-Guards are the quick and easy way to comply with the '24 Inch. Metacaulk Box Guards: Cover-Guards are single component fire-rated gaskets for use in electrical outlet boxes on fire-rated walls. Fitting Putty Pads will reinstate the fire rating of the partition for up to two hours (depending on the partition fire rating) preventing the passage of smoke and flames in a fire, and sound and air movement during service life, through the electrical socket, into the cavity. Putty Pads In order to be compliant with Building Regulations all electrical socket boxes that penetrate fire compartment walls need to be rated in. Unfortunately these pads are limited to new construction as the wall cavity must be open to install properly. /rebates/2fp2fHOLDRITE-HydroFlame-Firestop-Pro-7-in-x-7-in-Intumescent-Putty-Pad-HF-PP-12f315206280&. When electrical sockets and switches are installed in dry lining partitions, the original fire rating of the partition is compromised. The putty is manufactured and supplied in different shapes and forms for different applications. The acoustic putty pad/ box liner is designed to maintain the acoustic integrity of a wall when the soundproofing surface is penetrated with electrical sockets. ![]() Only one pad thickness (1/8') needed for a 1-2hr. NS Putty Pads are a pre-cut ablative pads designed for easy application around single and double electrical sockets where fire resistance must be upheld. The putty is hand workable, re-useable and reserviceable due to its non-setting properties. Pads have Sound Transmission Class (STC) Rating 60. SSP Putty is non-hardening and easily hand works around grouped cabling penetrations forming a re-enterable seal allowing for future work. The putty pads provide a Weighted Sound Reduction (Rw) of up to 67dB.Protecta® FR Putty is an easy to apply fire and sound rated sealant supplied as a non-setting putty. SSP Putty & Putty Pads STI Firestop SSP Putty & Putty Pads SpecSeal SSP Firestop Putty excels at sealing cabling penetrations and outlet boxes.Single number quantities were calculated in accordance with BS EN ISO 717-1 :1997.Measurement of airborne sound insulation was made in accordance with BS EN ISO 140-3:1995.The pads provide up to 2 hours fire protection. Tested in accordance with BS 476:Part 20:1987 and EN1366-3.They are used to fill gaps and seams in fire-rated walls and doors. Metal and Plastic Back Boxes 35mm and 47mm deep. Intumescent Putty Pads Buy Online FPC Fast Delivery Peace of Mind Eco Range Competitive Price Home > Electrical Fire Protection > Socket Switch Protection > Putty Pads Putty Pads From £ 1. Fire rated putty pads are essential components of fire protection systems in buildings. ![]() If Im paying labor to have it done, putty pads are most cost effective. They do sell pliable blocks of firestop sealant, but those are about 20 block. ![]()
0 Comments
Leave a Reply. |